Gating Automatic Mic Mixer Component

Relative Threshold

VIDEO TUTORIAL: Video tutorial available online for Gating Automatic Mic Mixer.

The Gating Automatic Mic Mixer is typically used in applications with multiple microphones, and at times, multiple microphones being used at the same time. The microphones in use can be prioritized using three different modes: Auto, Priority, and Filibuster or combinations of these. The channels open and close based on Threshold levels set for each channel, and optional Side Chain filters, or manual control. Attenuation controls help control feedback based on the number of microphones open at one time.

Noise Floor Tracking: Tracks the steady or slowly changing noise of equipment fans or HVAC. Instead of having to (repeatedly) adjust an absolute gate threshold that depends on the (varying) noise floor, a new relative threshold allows the gate to ride a (slowly) changing noise floor.

The Gating Automatic Mic Mixer is capable of up to 512 channels:

Controls

Controls are used during the design phase of a system to establish initial settings, and during normal system operation to make adjustments for different events. The controls can be adjusted only in Emulate or Run mode. Only Run mode actually processes audio. The controls listed below are divided into sections to match the Control Panel sections.

Once you establish the initial settings for a component, you can save those settings, along with all the other component's settings, in a Snapshot.

Side Chain Controls

The Side-Chain Filter is available only when Side-Chain Filter is set to Yes in the Properties.

Control

Function

Default/Range

Bypass

(button)

Bypasses any Side Chain filtering effects.

Off/On

Type

(drop-down)

Low-Pass - Allows frequencies below the Frequency setting to pass unattenuated.

High-Pass - Allows frequencies above the Frequency setting to pass unattenuated.

Band-Pass - Allows frequencies within the Bandwidth to pass unattenuated. The Bandwidth is centered on the Frequency setting,

Band-Stop - Allows all frequencies to pass unattenuated except those within the Bandwidth. The Bandwidth is centered on the Frequency setting. Sometimes known as a Notch Filter.

Parametric - Allows control of all three parameters: Bandwidth, Frequency, and Gain.

High-Shelf - Allows you to boost or attenuate signals above the set Frequency. Frequencies below the set Frequency are not affected.

Low-Shelf - Allows you to boost or attenuate signals below the set Frequency. Frequencies above the set Frequency are not affected.

Default = High-Pass

Bandwidth

(octave)

Sets the bandwidth of the filter.

The control is available with the Band-Pass, Band-Stop, Parametric Side Chain filters.

Default = 1.00

Range = 0.01 to 1.00

Frequency

(Hz)

Sets the upper, lower, or center frequency, depending on the filter.

The control is available with all filter types.

Default = 100

Range = 20 to 20 k

Gain

(dBFS)

Controls the gain of the Side Chain signal.

The control is available with the Parametric, Low-Shelf, High-Shelf filters.

Default = 0

Range = -100 to 20

Gate Controls

Control

Function

Default/Range

Last Mic On

(button)

Leaves the last microphone that was used in the open condition, until another microphone exceeds the Threshold.

On/Off

Threshold Level
Above Noise
(dB)

Noise Floor Tracking follows the steady or slowly changing noise of equipment fans, HVAC, and so on. In order for a channel to open its gate, the signal must exceed the noise floor by the amount set by the Threshold Level Above Noise control.

Default = 10

Range 0 to 50

Depth

(dB)

The Depth knob sets the amount of attenuation applied to any input channel when the channel's gate is closed.

 

Hold Time

(Seconds)

The Hold Time knob the sets minimum time an input stays open once it is opened, or the length of time an input stays open after the RMS input level drops below the Threshold Level. This is to prevent the gate from opening and closing due to momentary pauses in the input.

Default = 0.10

Range 0 to 1

Channel Controls

Control

Function

Default/Range

Open

Indicates if the associated channel is passing audio.

The Open LED is always on when the channel is in Manual Mode, and is always off when the Post-Gate Mute is enabled.

On = open

Off = closed

Default

The Default button allows a channel’s gate to be forced open when no signals exceed the threshold level. The Default and Last Mic On controls are mutually exclusive, and only one channel Default can be enabled at a time.

Off/On

Manual

The channel Manual control allows a channel to be removed from the auto-mix logic and excluded from NOM. The channel does not affect other channels and is always mixed, regardless of signal level.

Off/On

Signal Level Above Noise

(dB)

The Signal Level Above Noise meter indicates the signal level above the noise floor. It can be used as an aid in adjusting the Threshold Level Above Noise control.

Range = 0 to 50

Post-Gate Mute

The Post-Gate Mute button allows a channel to be included in the auto-mix logic but excluded from NOM. The channel is also excluded from the mix and its direct output is muted as well.

Unmuted/Muted

Post-Gate Gain

(dB)

The Post-Gate Gain control adjusts the post-gate direct output level and mix level. It does not affect the auto-mix logic.

Default = 0

Range = -100 to +10

Name

The Name field allows the channel to have a user-defined name.

User Defined

NOM (Number of Open Mics)

Control

Function

Default/Range

Max NOM

NOM is counted beginning at input 1 and once the maximum NOM has been reached gates will be closed for the remaining inputs. If you want a limited NOM to always contain the highest Priority (open) inputs, assign input 1 the highest priority, and assign the rest of the inputs in descending priority order.

Equal to the number of Channels assigned in the Properties.

Direct Outs NOM Atten.

Normally, the NOM attenuation is applied to the mix output only, not the direct outputs. However,you may want to process and/or mix the direct outputs externally and not use the built-in NOM-attenuated mix output. “Direct Outs NOM Atten.” allows you to get NOM attenuation to an external non-NOM mixer.

The default is ON, which applies the NOM attenuation to the direct outputs. In the OFF position, no attenuation is applied to the outputs.

On / Off

NOM Attenuation Type

(Dropdown list)

When Logarithmic is selected, the output is attenuated by the amount specified by the Attenuation Step control for each open channel every time NOM is doubled.

Assuming an Attenuation Step of 1 dB

NOM

Attenuation

1

0 dB

2

1 dB

4

2 dB

8

3 dB

When Linear is selected, the output is attenuated by the amount specified by the Attenuation Step control for each open channel every time NOM increases by 1.

Assuming an Attenuation Step of 1 dB:

NOM

Attenuation

1

0 dB

2

1 dB

3

2 dB

4

3 dB

Logarithmic / Linear

Attenuation Step

(dB)

The amount of attenuation added every time another mic opens, excluding the first mic opened.

Default = 3.00

Range = 0 to 20

Max Attenuation

(dB)

Sets the maximum amount of attenuation that can be applied to the output regardless of the NOM.

Default = 20

Range = 0 to 40

Response Time

(seconds)

Adjusts the time constant that determines the time it takes for the attenuation to be applied to the output when there is a change in the NOM.

Default = 0.02

Range = 0.02 to 10

NOM

(display)

The total number of open microphones.

0 to 512

Gain

(dB)

Measures the output gain with respect to the amount of attenuation applied. For example, 40 dB of applied attenuation would result in a -40 dB change in the output gain.

0 to -40

Mix

Control

Function

Default/Range

Mute

(button)

Mutes the Mix channel output. This mutes all Input channels for the Mix output but does not affect the individual Output channels.

Off/On

Gain

(dB)

Adjusts the Mix output channel gain. This applies to all Input channels for the Mix output, but does not affect the individual Output Channels.

Default = 0

Range = -100 to 20

Properties

The properties of a component are used in the Design phase to establish the size and characteristics of the component. They can be changed only in the Design Mode when the component is selected. Select and drag the Gating Automatic Mic Mixer component from the Schematic Library into the Schematic.

Property

Function

Choices

Channels

Sets the number of input and output channels for the Component.

2 to 512

Outputs

All inputs mixed into one output

One output channel per input channel, no mix is provided

Both

Mix Only

Channel Only

Mix and Channel

Side Chain Filter

Yes allows you to select various types of Side Chain filters in the Control Panel.

When you select Side Chain, the signal that controls the gate is filtered by the Side Chain settings. When Side Chain is not selected, the actual input signals are used to control the gates. The Side Chain filters do not affect the audio output, only the control of the gate.

No / Yes

Control Pins

The available Control Pins depend on settings in Properties.

Per Channel

Pin Name

Value

String

Position

Pins Available

Default

0

1

disable

enable

0

1

Input / Output

Manual

0

1

disable

enable

0

1

Input / Output

Name

user-defined text Input / Output

Open

0

1

false

true

0

1

Output

Post-Gate Gain

-100 to 10

-100 dB to 10 dB

0.000 to 1.00

Input / Output

Post-Gate Mute

0

1

unmuted

muted

0

1

Input / Output

Priority Level

1 to 10000

1 to 10000

0 to 1.00

Input / Output

Signal Level Above Noise

      Output

General

Pin Name

Value

String

Position

Pins Available

Bandwidth

.010 to 1.00

.010 to 1.00

0 to 1.00

Input / Output

Bypass

0

1

active

bypass

0

1

Input / Output

Direct Outputs NOM Attenuation

 

 

 

 

Frequency

10 to 20000

10 Hz to 20 kHz

0.000 to 1.00

Input / Output

Gain (Side Chain)

-100 to 20

-100 dB to 20 dB

0.000 to 1.00

Input / Output

Gate Depth

0 to 20

0 dB to 20 dB

0.000 to 1.00

Input / Output

Hold Time

0.00 to 10

0 ms to 1 s

0.000 to 1.00

Output

Last Mic On

0

1

disable

enable

0

1

Input / Output

Linear NOM Attenuation

0

1

disable

enable

0

1

Output

Maximum NOM

1 - n

1 to n

0.00 to 1.00

Input / Output

Maximum NOM Attenuation

0 to 20

0 dB to 40 dB

0.000 to 1.00

Input / Output

Mix Gain

-100 to 20

-100 dB to 20 dB

0.000 to 1.00

Input / Output

Mix Mute

0

1

unmute

mute

0

1

Input / Output

NOM Response Time

0.0001 to 1

.100 ms to 1 s

0.000 to 1.00

Input / Output

NOM Attenuation Step

0 to 20

0 dB to 40 dB

0.000 to 1.00

Input / Output

NOM Gain

-100 to 20

-100 dB to 20 dB

0.000 to 1.00

Output

Number of Open Mics

0 to n

0 to n

0 to 1.00

Output

Threshold Level Above Noise

0.00 to 50 0dB to 50.0dB 0.000 to 1.00 Input / Output
Type

1.00

2.00

3.00

4.00

5.00

6.00

7.00

Low-Pass

High-Pass

Band-Pass

Band-stop

Parametric

Low-Shelf

High-Shelf

0

.167

.333

.500

.667

.833

1.00